ISO Bolt Proof Load and Breakage Table 898-1

proof load and breakage of iso bolts

ISO Bolt Proof Load and Breakage Table 898-1

Proof charge (no permanent deformation) and minimum tensile breaking load for coarse metric thread screws.

  • NormaISO 898-1
  • Lines20
  • Updated
Go to table
ISO Bolt Proof Load and Breakage Table 898-1

How to use

  • As = tensile resistant area. Min breaking load. = As × Rm min. (8.8 = 800 MPa up to M16; above M16 o Rm min. go up to 830 MPa — value in this column is in favor of safety).
  • For assembly preload, normally use 70 % a 75 % of proof load — see also Torque and Preload Table.
ThreadAs
mm²
Proof charge
8.8
kN
Proof charge
10.9
kN
Proof charge
12.9
kN
My Ruptura.
8.8
kN
My Ruptura.
10.9
kN
My Ruptura.
12.9
kN
M35,032,94,24,94,05,26,1
M3,56,783,95,66,65,47,18,3
M48,785,17,38,57,09,110,7
M514,28,211,813,811,414,817,3
M620,111,616,719,516,120,924,5
M728,916,824,028,023,130,135,3
M836,621,230,435,529,338,144,7
M1058,033,748,156,346,460,370,8
M1284,348,970,081,867,487,7102,8
M1411566,795,5112,092,0119,6140,3
M1615791,0130,0152,0125,6163,3191,5
M18192115,0159,0186,0153,6199,7234,2
M20245147,0203,0238,0196,0254,8298,9
M22303182,0252,0294,0242,4315,1369,7
M24353212,0293,0342,0282,4367,1430,7
M27459275,0381,0445,0367,2477,4560,0
M30561337,0466,0544,0448,8583,4684,4
M33694416,0576,0673,0555,2721,8846,7
M36817490,0678,0792,0653,6849,7996,7
M39976586,0810,0947,0780,81.015,01.190,7

Source: ISO 898-1:2013 (proof loads via Bossard, Technical Resources F-004).